Construction:Â Tube: NR& SBR or EPDM synthetic rubber.
            Reinforcement: One ply High tensile polyester fiber braided.
            Cover: NR & SBR or EPDM synthetic rubber.
Temperature: -30ºC - +80ºC
Color:Â Black, Red, Yellow, Blue, Green, Orange, etc.
Application:Â Mainly used for conveying of water, air, insert gas and water in mining, construction, engineering, shipbuilding, steel production etc.
Standard length: 50ft (15m), 100ft(30m)
Specification of hose:
Item code | Inner Diameter | Outer Diameter | Working Pressure | Burst Pressure | Length | |||
inch | mm | mm | bar | psi | bar | psi | ft/pc | |
HPR1 | 3/4" | 19 | 27 | 10 | 150 | 30 | 450 | 50 |
HPR2 | 3/4" | 19 | 27 | 10 | 150 | 30 | 450 | 100 |
HPR3 | 5/8" | 16 | 23 | 10 | 150 | 30 | 450 | 50 |
HPR4 | 5/8" | 16 | 23 | 10 | 150 | 30 | 450 | 100 |
Specification of fittings:
Brass Heavy-Duty Male and Female MXF GHT/NH solid garden hose fittings
 Rubber contractor garden hose Assembly
Construction:Â Tube: NR& SBR or EPDM synthetic rubber.
            Reinforcement: One ply High tensile polyester fiber braided.
            Cover: NR & SBR or EPDM synthetic rubber.
Temperature: -30ºC - +80ºC
Color:Â Black, Red, Yellow, Blue, Green, Orange, etc.
Application:Â Mainly used for conveying of water, air, insert gas and water in mining, construction, engineering, shipbuilding, steel production etc.
Standard length: 50ft (15m), 100ft(30m)
Specification of hose:
Item code | Inner Diameter | Outer Diameter | Working Pressure | Burst Pressure | Length | |||
inch | mm | mm | bar | psi | bar | psi | ft/pc | |
HPR1 | 3/4" | 19 | 27 | 10 | 150 | 30 | 450 | 50 |
HPR2 | 3/4" | 19 | 27 | 10 | 150 | 30 | 450 | 100 |
HPR3 | 5/8" | 16 | 23 | 10 | 150 | 30 | 450 | 50 |
HPR4 | 5/8" | 16 | 23 | 10 | 150 | 30 | 450 | 100 |
Specification of fittings:
Brass Heavy-Duty Male and Female MXF GHT/NH solid garden hose fittings
Â
Sub-controller of LED applying system. The DMX-S8 receives the pixel data frame sent by the RTP-S1500 Main Controller. According to the address set by itself, the corresponding data in the pixel frame is taken out. After the format is adjusted, the data is sent out from the controlling port at a specific timing sequence to control the LED light to change color. Set up 2 RJ45 network interfaces; When using unshielded Twisted Pair, the distance of transmission from the main controller to the sub-controller and sub-controller to sub-controller is more than 100 meters; Connect to the switch for network to extend the distance of transmission; Single controller can connect up to 16 computer; Automatically identify its position in the system; Set up 8 DMX512 controlling ports with auto-addressing function. The number of single-port controlling pixels is 170 full-color pixels, 512 monochrome pixels, and the type of connector is the pluggable terminal; Each port conduct optical isolation protecting to ensure the stability of the entire controlling system;
Sub-controller
Sub Controller,DMX 512 Sub Controller,Auto-addressing Sub Controller,LED Lighting System Sub Controller
StrongLED Lighting Systems (Suzhou) Co., Ltd. , https://www.strongledcn.com