The winter is undoubtedly very cold. If heating has not been turned on at this time, it must be unbearable. Therefore, heating must be necessary, and floor heating is a relatively common heating method in modern times. It has a lot of attention to be paid when using it. Question, today Xiao Bian will take you to find out how warm the water temperature is to 50 degrees at room temperature ? Let's take a look at how hot it is when hot water is not hot.
First, to warm the water temperature of 50 degrees at room temperature
To warm the water temperature of 50 degrees at room temperature ? The country has a strict specification for the temperature of the water temperature to warm, warm water temperature can not be higher than 60 degrees, of course, how much water temperature set with the actual indoor laying density, loop length, maintenance structure of the insulation, etc. Great relationship.
Generally, the laying density of warm water pipes is 200mm, and it must be below 250mm. The loop length should be less than 100m. If the water temperature is 50 degrees, the indoor temperature is generally 20 degrees, and the ground temperature is generally 30 degrees.
Second, the hot water is not hot water is how the matter
1, the pipeline pressure is not enough
If the heating source is not warm enough, the backwater of the floor heating may not be warm because the water will circulate in the floor heating pipeline and it will need some pressure. If the pressure is not enough, the return water will not be hot. In this case, it is recommended to install a circulation pump to increase the circulation of hot water to achieve the desired heating effect.
2, the circuit is too large
Recycled water approaches the road, forming a circuit in your radiator that is too large, creating a large circulation that is under pressure.
3, gas inside the pipeline
To warm the pipe, the backwater is not hot, there is gas in the pipe, which leads to the hot water can not enter the loop to circulate. You need to close the water return valve and manually open the floor heating valve to exhaust.
4, filter clogging
It may also be that the quality of the hot water supply is too dirty, causing the filter to become clogged and not allowing it to circulate properly. You can use a loose-end wrench to open the filter, clean the strainer inside, and reinstall it.
5, do not clean long-term heating
The maintenance of the floor heating equipment is not timely. If it is not in place, the floor heating will not be warm. The 1mm thick scale will cause the water temperature to drop by 6°C. If it is cleaned off occasionally, the inner diameter of the floor heating pipe will gradually narrow, the water flow will become smaller, and the temperature will decrease. If there is a failure, it may even cause embedding in the floor heating pipe. Therefore, the floor heating pipe must be cleaned once in 3-5 years, and it must be maintained before heating.
6, the valve is not open
If the main valve is not opened, it will cause the hot water in the inlet water to be not hot. This will check the main valve of the floor heating supervisor and the manifold to see if it is in the closed state, and if so, it can be opened.
7, geothermal construction issues
Without professional training of construction workers or construction is not standardized, it is easy to bend the pipeline, flattening, which will make the water flow, resistance increases.
Editor's summary: The above is about the warm water temperature of 50 degrees at room temperature and how hot water backwater is not hot matter of introduction, although the floor heating is good, but the use of energy consumption is relatively large, so when laying pipe installation and use must Reasonable, this is the best.